Precautions
Caution Eye and Skin Irritant
SDS
For Use With
Product Information
Type | Spray Adhesive |
Color | White |
Taggants | None |
Trowel | N/A |
Coverage | 140 – 150 sq. ft./bottle (13-16 sq. m.) Luxury Vinyl Tile and Commercial Vinyl Sheet 160 – 185 sq. ft./bottle (16-19 sq. m.) Vinyl Composition Tile |
Units | 22 oz bottle |
Open Time | Until dry-to-touch: approximately 30 minutes or more |
Working Time | Up to 4 hours (working times may vary based on job conditions, substrates, temperature and humidity) |
Shelf Life | 2 years, unopened |
RH (ASTM F2170) | See Moisture Testing |
pH | See Moisture Testing |
MVER (ASTM F1869) | See Moisture Testing |
Freeze/Thaw Stable | No, keep from freezing Store inside at a temperature of 60 – 100 degrees F. |
VOC Content | 0 g/L; calculated and reported, SCAQMD 1168 |
Clean Up | Wet– clean, white cloth with neutral detergent and water Dry– clean, white cloth and mineral spirits |
Subfloors | All grade levels of concrete, existing resilient floors, ceramic, terrazzo, marble, polymeric poured floors and suspended wood |
Advantages | Moisture and alkali resistant Strong, early grab AGIS Guarantee Nonflammable, ammonia-free and low odor Contains low or no organic solvents Suitable for heavy rolling loads Allows immediate traffic Vinyl sheet can be heat welded immediately |
Language | English/Spanish | English/French |
Size | 22 oz bottle | 22 oz bottle |
Item # | bottle – FP00SPR601 | bottle– FPS-SPR601 |
Bottle UPC | 0 42369 85020 9 | 0 42369 85021 6 |
Carton UPC | 1 00 42369 85020 6 | 1 00 42369 85021 3 |
Bottle Dimensions | 1-bottle – 2.5” L x 2.5” W x 11.25” H | 1-bottle – 6.35 cm L x 6.35 cm W x 28.6 cm H |
Carton Dimensions | 5.75″ L x 8.5″ W x 13″ H | 14.6 cm L x 21.6 cm W x 33 cm H |
Carton Weight | 10 lbs | 4.5 kg |
Items per Carton | 6 bottles 1 spray clip | 6 bottles 1 spray clip |
Cartons per Pallet | 96 | 96 |
Warranty
When Armstrong Flooring Flip Spray Adhesive is used with a recommended Armstrong Flooring floor application, the Armstrong Flooring Guaranteed Installation System warranty applies.
Sustainability
FloorScore Certificates – Adhesives
LEED Credits: EQ 4.1
Sustainable Design Information
LEED Credit Information – Installation Products
Recommended Substrates
DO NOT USE OVER: Concrete with excessive moisture and/or alkali; existing cushion-backed resilient flooring; substrates treated with fire-retardant chemicals, fungicides, preservatives, release agents, adhesive removers, sealers, curing compounds or other incompatible treatments
Will bond to all substrates listed below but refer to flooring installation system for specific installation recommendations:
- Concrete on (all grade levels) according to ASTM F710 and Preparation of Concrete Subfloors
- Suspended Wood Subfloors and Panel Underlayments
- Existing well-bonded resilient flooring; not perimeter-bonded or cushion-backed
- Ceramic tile, terrazzo, marble and polymeric-poured floors
- Properly mixed and applied powder underlayments and embossing levelers
- Primed, poured-in-placed gypsum subfloors
- Radiant-heated subfloors where the surface temperature does not exceed 85oF (29o C)
DO NOT USE OVER: Concrete with excessive moisture and/or alkali; existing cushion-backed resilient flooring; substrates treated with fire-retardant chemicals, fungicides, preservatives, release agents, adhesive removers, sealers, curing compounds or other incompatible treatments
Application Instructions
SEE ATTACHMENT BELOW FOR SPRAY PATTERN GUIDE.
- Seams in sheet vinyl must be heat welded only. Seams may be welded immediately.
- Condition area to be installed, adhesive, and tile at 65° F (18° C) or above for 48 hours before and 48 hours after installation.
- Sweep or vacuum floor, and use a damp mop to pick up remaining dust.
- Subfloor must be smooth, sound, dry, clean, and free of dirt, wax, polish, paint, and all other foreign matter which may interfere in a good bond, including curing agents and sealers.
- Always run a moisture and alkali test over concrete on any grade level or any other substrate over on- or below-grade concrete. For accurate results, curing agents must be removed in areas where tests will be run. Relative humidity in-situ probe results should not exceed 95%. Alkali readings should be 5 to 11.
- Shake bottle well. Point the bottle downward and press the side of the nozzle tip.
- Walk back and forth at a steady pace. Do not use a sweeping motion.
- Use a shield to protect walls from overspray. A shield can be as simple as a piece of cardboard.
- Spray the perimeter first, then fill in the rest of the room.
- Allow adhesive to set open until dry to the touch, approximately 30 minutes. When dry to the touch, the adhesive will be tacky with no transfer to fingers.
- Wet adhesive, overspray or drips should be cleaned and smoothed immediately using a cloth moistened with soap and water. Drips can be smoothed out with spatula or flat trowel.
- Between uses, clean the spray tip with a clean wet cloth to prevent accumulation of dried adhesive.
- Install and fit all material within 4 hours. Working time will vary based on job conditions, substrate, temperature and humidity.
- Roll the floor once immediately after installation with 100-lb roller
- Remove wet adhesive residue using a clean, white cloth dampened with soapy water. Use mineral spirits for dried adhesive residue carefully following warnings on container.
- Do not wet wash or scrub flooring for at least five days after installation.