Precautions
Caution Eye and Skin Irritant
SDS
S-202 Static Dissipative Tile (SDT) Adhesive SDS
For Use With
Product Information
Copper (Alloy 110) grounding strips supplied with adhesive. A see-through, self-adhering envelope is taped to the top of the lid of the pail.
4 gallon pails contain 2 each copper grounding strips, 2″ wide x 12′ long. The thickness is .003″.
1 gallon pails will contain 1 copper strip 2″ wide x 6′ long with a thickness of .003″.
*1 Gallon copper strip package is now available for order if extra copper strips are desired. See Carton/Pallet Table below.
Type | Water-based resin |
Color | Black |
Taggants | None |
Trowel | Fine notch (1/32″ deep, 1/16″ wide, 5/64″ apart), U-notch![]() |
Coverage | Approximately 150 sq. ft. /gal. (14 sq. m) |
Units | 1 gallon (3.78 L) and 4 gallon (15.14 L) |
Open Time | Until dry to touch; 60 minutes or more |
Working Time | Up to 6 hours (working times may vary based on job conditions, substrates, temperature and humidity) |
RH (ASTM F2170) | Effective October, 2024: 90% Prior to October, 2024: 75% |
pH | Effective October, 2024: 12 Prior to October, 2024: 5-9 |
MVER (ASTM F1869) | N/A |
Shelf Life | 1 year, unopened |
Freeze/Thaw Stable | No, keep from freezing |
VOC Content | < 50 g/L; calculated and reported, SCAQMD 1168 |
Clean Up | Wet or Dry- clean, white cloth and mineral spirits |
Subfloors | All grade levels of concrete and suspended wood. Ceramic, terrazzo, polymeric poured and certain metal subfloor when properly prepared with appropriate cementitious patch or leveling compound Radiant Heated subfloors where the surface temperature does not exceed 85° F (29° C) |
Advantages | Moisture and alkali resistant Long working time (up to 6 hours) |
Manufacturing Location | USA |
Language | English/French/Spanish | English/Spanish | English/French |
Size | 1-gallon (3,78L) | 4-gallon | 15.14L |
Carton Item No. | 1-gallon (3,78L) – 00202108 | 4-gallon – 00202418 | 15.14L – S-202605 |
Item/Carton UPC | 1-gallon (3,78L) – 042369113878 | 4-gallon – 042369070591 (order individually) | 15.14L – 042369082426 (order individually) |
Carton Dimensions | 1-gallon (3,78L) – 8” L x 8” W x 8” H | 4-gallon – 13” L x 13” W x 12.5” H | 15.14L – 13” L x 13” W x 12.5” H |
Carton Weight | 1-gallon (3,78L) – 10 lbs. | 4-gallon – 37.17 lbs. | 15.14L – 16.86 kg |
Items per Carton | 1-gallon (3,78L) – Containers sold individually | 4-gallon – Containers sold individually | 15.14L – Containers sold individually |
Cartons per Pallet | 1-gallon (3,78L) – 100 | 4-gallon – 48 | 15.14L – 48 |
Additional Copper Strips | (1) Strip 2″ wide x 6’ long- FP00202COP | (1) Strip 2″ wide x 6′ long- FP00202COP | N/A |
Warranty
When Armstrong Flooring S-202 is used with a recommended Armstrong floor application, the Armstrong Guaranteed Installation System warranty applies.
Sustainability
FloorScore Certificates – Adhesives
LEED Credits: EQ 4.1
Sustainable Design Information
LEED Credit Information – Installation Products
Recommended Substrates
Will bond to all substrates listed below, but refer to the flooring installation system for specific installation recommendations:
- Concrete on (all grade levels) according to ASTM F710 and Preparation of Concrete Subfloors
- Suspended Wood Subfloors and Panel Underlayments
- Properly mixed and applied powder underlayments and embossing levelers
- Ceramic, Terrazzo, Marble, Polymeric (seamless) Floors, or Metal – when properly prepared with appropriate cementitious patch or leveling compound
- Radiant-heated subfloors where the surface temperature does not exceed 85oF (29o C)
DO NOT USE OVER: Concrete with excessive moisture and/or alkali; existing resilient flooring; substrates treated with fire-retardant chemicals, fungicides, preservatives, release agents, adhesive removers, sealers, curing compounds or other incompatible treatments
Application Instructions
- Condition area to be installed, adhesive, and tile at 65° F (18° C) or above for 48 hours before, during, and for 48 hours after installation.
- Subfloor must be smooth, sound, dry, clean, and free of dirt, wax, polish, paint, and all other foreign matter which may interfere in a good bond, including curing agents and sealers.
- Always run a moisture and alkali tests over concrete on any grade level or any other substrate over on- or below-grade concrete. For accurate results, curing agents must be removed in areas where tests will be run. Moisture test results should not exceed 90% for a relative humidity in-situ probe test. Alkali readings should not exceed pH of 12.
- Stir any liquid on the surface into the adhesive and full spread using the recommended trowel notching.
- Allow adhesive to set open until dry to the touch, approximately 60 minutes. When dry to the touch, the adhesive will be tacky with no transfer to fingers.
- Install and fit all tile within 6 hours. Working time will vary based on job conditions, substrate, temperature and humidity.
- Place 18 inches of the copper grounding strips into the adhesive at predetermined locations. Allow 6 inches to protrude from the edge of the floor up the wall so the strip can later be connected to a ground. Cover the part of the strip that’s been placed in the adhesive with more adhesive.
- Allow the adhesive on the copper grounding strips to dry to the touch and then install the tile over the strips.
- Roll tile in both directions with a 100-pound roller.
- Use mineral spirits to remove wet or dried adhesive residue carefully following warnings on container.
- Do not wet wash or strip tile for at least five days after installation.
Product Image